The premium backwater pumping station for faecal and non-faecal wastewater is equipped with a pump and a mechanical closure system. The water normally drains to the sewer via natural fall. During the backwater phase, the water drains via the pump with integrated macerator, against the backwater in the sewer. It is controlled by a plug-in ready control unit.
Variant
Emergency closure: yes
Pump control: Control unit
Motor-driven backwater flaps: 1
General characteristics
Colour: black
Nominal size (DN): 150
Outer diameter (OD): 160 mm
Type of wastewater: for wastewater with and without sewage
Installation situation: exposed drainage pipe
Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
Approval: Z-53.2-388
Cable length: 5 m
Dimensions
Net weight: 16,5 kg
Gross weight: 22 kg
Vertical drop between inlet and outlet: 9 mm
Length: 656 mm
Height: 422 mm
Packaging dimension: length: 656,1 mm
Packaging dimension: width: 350 mm
Packaging dimension: height: 421,8 mm
Coverage features
Type of cover: Protective cover
Cover material: Polymer
Colour of cover: transparent
Width of cover: 350 mm
Height of cover: 165 mm
Length of cover: 542 mm
Locking: Clip closure
Pumping device
Pump: SPZ 1000
Number of pumps: 1
Weight, pump: 10 kg
Connection type: coded plug
Rated current: 5,2 A
Protection class: I
Insulation class: F
Cos phi - power factor: 0,97
Protection class (pump): IP 68 (3m/48h)
Temperature monitoring: integrated
Max. temperature (permanent) of conveyed material: 40 °C
Max. pumping capacity: 11,5 m³/h
Max. pumping height: 10 m
Speed: 2800 U/min
Power P1: 1,2 kW
Power P2: 0,69 kW
Operating mode: S3 - 50 %
Type of fuse required (electrical protection): C 16 A
Type of pump connection cable: H07RN-F 3G 1.5 mm²
Impeller type: Macerator
Motor connection cable type: ÖPVC-JB/OB 300/500 V/3 x 0,75 mm2 mm²
Sensor connection cable type: ÖPVC-JB/OB 300/500 V/3 x 0,75 mm2 mm²
Length of mains cable for pump: 5 m
Control
Control unit: Standard
Protection class control unit: IP 54
Mains frequency: 50 Hz
Operating voltage: 230 V
Connection type: coded plug
Log book function: yes
Battery buffering: yes
Self-diagnosis system (SDS): yes
Type of fuse required (electrical protection): C 16 A