The lifting station for faecal-free wastewater is equipped with one or two submersible pumps and a backflow preventer. The collection tank made of permanently resistant polymer (PE) offers universal connection options. One-handed closures enable easy removal of the integrated components.
Variant
Type of system: duo pump
Resistant: Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems
Pump control: Control unit
Backwater protection: integrated
Pressure pipe connection: horizontal
General characteristics
Colour: black
Standard: EN 12050-2
Type of wastewater: without sewage
Installation situation: free-standing installation
Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
System type: Duo
Dimensions
Net weight: 19,99 kg
Gross weight: 29,8 kg
Length: 500 mm
Width: 500 mm
Height: 720 mm
Packaging dimension: length: 610 mm
Packaging dimension: width: 610 mm
Packaging dimension: height: 490 mm
Tank/drain body
Pressure pipe connection (DN): 32
Pressure pipe connection (OD): 40 mm
Venting connection (DN): 70
Distance from centre of outlet pipe to tank bottom: 258 mm
Distance pipe bottom inlet to tank bottom: 530 mm
Distance from centre of inlet pipe to tank bottom: 585 mm
Inlet max. scoring (DN): 100 mm
Inlet nominal size (OD): 110 mm
Inlet nominal size (DN): 100 mm
Number of inlets: 1
Tank volume: 55 l
Coverage features
Cover material: Polymer
Colour of cover: black
Width of cover: 420 mm
Height of cover: 70 mm
Length of cover: 420 mm
Locking: wedged
Pumping device
Pump: GTF 500
Number of pumps: 2
Weight, pump: 6 kg
Connection type: Schuko (earthed contact) 2-pin
Rated current: 2,7 A
Length of mains cable for pump: 5 m
Protection class: I
Insulation class: F
Cos phi - power factor: 0,91
Protection class (pump): IP 68
Temperature monitoring: integrated
Max. temperature (permanent) of conveyed material: 40 °C
Max. pumping capacity: 10 m³/h
Max. pumping height: 8 m
Speed: 2800 U/min
Power P1: 0,6 kW
Power P2: 0,36 kW
Operating mode: S1
Type of fuse required (electrical protection): C 16 A
Type of pump connection cable: H07RN-F 3G 1.5 mm²
Impeller type: Multi-vane impeller
Free passage: 10 mm
Control
Control unit: Comfort
Alarm sensor: optical probe
Level measurement instrument: Immersion pipe
Type of level measurement: pneumatic
Protection class control unit: IP 54
Mains frequency: 50 Hz
Operating voltage: 230 V
Connection type: Schuko (earthed contact) 2-pin
Length of mains cable for control unit: 1,4 m
Potential-free contact: optional
GSM interface: yes
USB interface: yes
Log book function: yes
Multi-line display: yes
Battery buffering: yes
Self-diagnosis system (SDS): yes
Rated current: 2,7 A