Product 11 of 14
The pumping station without sewage wastewater is equipped with one or two submersible pumps and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an open pump tank with universal connection options. Quick-release closures enable the integrated components to be removed easily. The KESSEL modular system provides different engineering chamber options as accessories for the further layout.
Variant
Note on installation depth: in combination with a chamber module
Type of system: Single unit
Shut-off valve: without shut-off valve
Passage seal for conduit pipe (DN): 100
Access steps: yes
Passage seal for ventilation pipe (DN): 100
Installation: Wet installation
Pump control: Float switch
Backflow preventer: integrated
Pressure pipe connection: horizontal
General characteristics
Colour: black
Standard: EN 12050-2
Type of wastewater: without sewage
Installation situation: underground installation
Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
System type: Mono
Dimensions
Net weight: 98 kg
Gross weight: 113 kg
Groundwater resistant from lower edge of base section: 3000 mm
Length: 1330 mm
Width: 1240 mm
Height: 914 mm
Packaging dimension: length: 1300 mm
Packaging dimension: width: 1300 mm
Packaging dimension: height: 1050 mm
Tank/drain body
Pressure pipe connection (DN): 32
Pressure pipe connection (OD): 40 mm
Distance from centre of outlet pipe to tank bottom: 780 mm
Distance pipe bottom inlet to tank bottom: 607 mm
Distance from centre of inlet pipe to tank bottom: 687 mm
Distance from inlet pipe invert to top of tank: 281 mm
Inlet max. scoring (DN): 150 mm
Inlet nominal size (OD): 160 mm
Inlet nominal size (DN): 150 mm
Number of inlets: 1
Clear width of tank (LW): 1000 mm
Pumping volume: 100 l
Pumping device
Pump: GTF 1200
Number of pumps: 1
Weight, pump: 10 kg
Connection type: coded plug
Operating voltage: 230 V
Protection class: I
Insulation class: F
Cos phi - power factor: 0,98
Protection class (pump): IP 68 (3m)
Temperature monitoring: integrated
Max. temperature (permanent) of conveyed material: 40 °C
Max. pumping capacity: 15,5 m³/h
Max. pumping height: 9 m
Speed: 2650 U/min
Power P1: 1,4 kW
Power P2: 0,84 kW
Operating mode: S3 - 50 %
Type of pump connection cable: H07RN-F 3G 1.5 mm²
Impeller type: Multi-vane impeller
Type of fuse required (electrical protection): C 16 A
Length of mains cable for pump: 10 m
Rated current: 6,2 A
Control
Level measurement instrument: Float switch
Type of level measurement: mechanical
Mains frequency: 50 Hz
Operating voltage: 230 V
Connection type: coded plug
Length of mains cable for control unit: 1,4 m
Variant
Note on installation depth: in combination with a chamber module
Type of system: Single unit
Shut-off valve: without shut-off valve
Passage seal for conduit pipe (DN): 100
Access steps: yes
Passage seal for ventilation pipe (DN): 100
Installation: Wet installation
Pump control: Float switch
Backflow preventer: integrated
Pressure pipe connection: horizontal
General characteristics
Colour: black
Standard: EN 12050-2
Type of wastewater: without sewage
Installation situation: underground installation
Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
System type: Mono
Dimensions
Net weight: 98 kg
Gross weight: 113 kg
Groundwater resistant from lower edge of base section: 3000 mm
Length: 1330 mm
Width: 1240 mm
Height: 914 mm
Packaging dimension: length: 1300 mm
Packaging dimension: width: 1300 mm
Packaging dimension: height: 1050 mm
Tank/drain body
Pressure pipe connection (DN): 32
Pressure pipe connection (OD): 40 mm
Distance from centre of outlet pipe to tank bottom: 780 mm
Distance pipe bottom inlet to tank bottom: 607 mm
Distance from centre of inlet pipe to tank bottom: 687 mm
Distance from inlet pipe invert to top of tank: 281 mm
Inlet max. scoring (DN): 150 mm
Inlet nominal size (OD): 160 mm
Inlet nominal size (DN): 150 mm
Number of inlets: 1
Clear width of tank (LW): 1000 mm
Pumping volume: 100 l
Pumping device
Pump: GTF 1200
Number of pumps: 1
Weight, pump: 10 kg
Connection type: coded plug
Operating voltage: 230 V
Protection class: I
Insulation class: F
Cos phi - power factor: 0,98
Protection class (pump): IP 68 (3m)
Temperature monitoring: integrated
Max. temperature (permanent) of conveyed material: 40 °C
Max. pumping capacity: 15,5 m³/h
Max. pumping height: 9 m
Speed: 2650 U/min
Power P1: 1,4 kW
Power P2: 0,84 kW
Operating mode: S3 - 50 %
Type of pump connection cable: H07RN-F 3G 1.5 mm²
Impeller type: Multi-vane impeller
Type of fuse required (electrical protection): C 16 A
Length of mains cable for pump: 10 m
Rated current: 6,2 A
Control
Level measurement instrument: Float switch
Type of level measurement: mechanical
Mains frequency: 50 Hz
Operating voltage: 230 V
Connection type: coded plug
Length of mains cable for control unit: 1,4 m
Declaration of Conformity
DOC KTP + GTFDeclaration of Performance (DOP)
DOP Aquapump XLDimensional drawings
mz_8743009_184702.pdfDWG data
8743009_01062017_184701.dwgInstallation and operating instructions
Control unit 230 V Mono/DuoTest report
zz_187580.pdf