The separator for greasy wastewater for underground installation consists of a grease separator and an engineering chamber. The two-piece system made of permanently resistant polymer (PE) is equipped with an integrated sludge trap and an integrated sampling device. Access for cleaning and maintenance work is provided by inspection openings, with polymer upper sections for continuously adjustable height and level compensation. The innovative Shredder-Mix-System with integrated macerating system is responsible for homogenising and circulating the tank contents. Cleaning and odour-neutral disposal takes place via an exterior submersible pump which is installed in a separate engineering chamber and can be disconnected from the tank by a shut-off valve. The fully automatic program run is controlled by a user-friendly control unit with multi-line display that can be integrated into the building management system through a potential-free contact. The control unit with 10 m long cable is installed in the engineering chamber in the factory. Cleaning and disposal can be started remotely using the remote control. Thanks to the customisable cleaning program with fast-selection function, cleaning can be adapted to the local circumstances as required. Observance of the Drinking Water Hygiene Directive can be guaranteed through the fully automatic rinsing of the drinking water pipes. The refill inlet and solenoid valves must be installed in a dry room on site. The connections between the grease separator and the engineering chamber as well as the reserve conduits and the connections must be made on site. (see connection set 917421). A load distribution slab must be installed on site for load class D. The reinforcement drawings are available from KESSEL. 20 year polyethylene warranty.
Variant
Note on installation depth: Installation in the ground, frost-free depth 1200 mm
Shut-off valve: yes
Disposal variant: Auto Mix & Pump
Shredder-Mix-System: yes
Sludge bucket: no
Nominal size (NS): 1,00
SonicControl: no
Disposal system: Disposal pump
Refill inlet in accordance with DIN 1988: yes
Type of disposal: automatic disposal and cleaning system
Water supply: 2 solenoid valves 1"
Sampling device: Type NBG
Load-bearing capacity (DIN 19901): E2
General characteristics
Standard: EN 1825: 2004
Dimensions
Net weight: 440 kg
Gross weight: 460 kg
Groundwater resistant from lower edge of base section: 3000 mm
Diameter: 648 mm
Max. length: 2790 mm
Installation depth: 760 - 1200 mm
Required access area, length: 1425 mm
Required access area, width: 1235 mm
Packaging dimension: length: 3812 mm
Packaging dimension: width: 1287 mm
Packaging dimension: height: 1918 mm
Tank/drain body
Distance pipe bottom outlet to tank bottom: 595 mm
Distance pipe bottom inlet to tank bottom: 705 mm
Outlet nominal size (OD): 110 mm
Outlet nominal size (DN): 100 mm
Inlet nominal size (OD): 110 mm
Inlet nominal size (DN): 100 mm
Connection inlet/outlet sockets: PE-HD pipes in accordance with DIN 19537, PVC-KG pipes in accordance with DIN 19534, PP or AS
Clear width of tank (LW): 1000 mm
Clear width of entry (LW): 600 mm
Coverage features
Type of cover: Cover plate
Cover material: Grey iron
Colour of cover: black
Locking: unlocked
Load class: B 125 (EN 124)
Tightness: odour-tight and surface water resistant
Wastewater contents
Separator contents: 230 l
Total volume: 370 l
Contents of sludge trap: 140 l
Storage quantity of grease: 70 l
Pumping device
Pump: SPF 300 IP68
Number of pumps: 1
Weight, pump: 44 kg
Connection type: Direct connection
Protection class: I
Insulation class: F
Protection class (pump): IP 68
Temperature monitoring: integrated
Max. temperature (permanent) of conveyed material: 40 °C
Max. pumping capacity: 60 m³/h
Max. pumping height: 17 m
Speed: 2850 U/min
Power P1: 3,6 kW
Power P2: 3 kW
Operating mode: S2 - 30 min.
Type of fuse required (electrical protection): Fuse protection through control unit 400 V
Type of pump connection cable: H07RN-F 7G 1.5 mm²
Impeller type: Radial impeller with macerating system
Length of mains cable for pump: 5 m
Rated current: 6,2 A
Control
Control unit: yes
Motor protection switch: yes
Type of fuse required (RCD): 30 mA
Protection class control unit: IP 54
Mains frequency: 50 Hz
Operating voltage: 400 V
Connection type: Direct connection
Potential-free contact: yes
GSM interface: no
USB interface: yes
Log book function: yes
Multi-line display: yes
Battery buffering: no
Self-diagnosis system (SDS): yes
Type of fuse required (electrical protection): Fuse protection through control unit 400 V